Pharmacode exists for one reason: to prove, mechanically and at line speed, that the carton, leaflet or foil in front of the machine belongs to the product being packed. MEF code inspection stations read Laetus Pharmacode, verify batch and expiry text by OCR/OCV, and decode and grade 1D and 2D barcodes - stopping the line or rejecting the pack the instant a code does not match the batch.

Every packaging line already prints codes. Very few verify them, and an unverified code is a claim rather than a control.
Laetus Pharmacode - binary bar code, single and two-track, in any print orientation - decoded and compared to the value assigned to that batch. The classic anti-mix-up control on cartons, leaflets and foils.
Batch, MFG and EXP text is read by OCR and then verified against the batch record by OCV. A carton carrying last month's expiry is rejected, not merely logged.
Code 128, GS1-128, EAN/UPC, ITF-14, QR and GS1 DataMatrix decoded and graded to ISO/IEC 15415 and 15416, so print degradation is visible before scanners start failing downstream.
A code mismatch usually means a material mix-up, not a single bad pack. The recipe decides per defect: reject the pack, or stop the line and hold the batch.
Unique code printing, verification and parent-child aggregation to shipper for US DSCSA, EU FMD and other national schemes, with the data files the regulators expect.
Ink-jet, laser, thermal transfer and offset pre-print each need different lighting and different tolerances. We design for the one you actually use.
21 CFR Part 11 audit trail, e-signature, locked recipes, and an image of every reject with batch, timestamp and reason code.
On the cartoner, the blister machine's foil path, the leaflet feeder or the labeller discharge - wherever the code is printed or applied.
Pharmacode is checked at the point of feed, because that is where a mix-up enters the line.
Indicative figures for the standard build. Every machine is engineered to your container, product and throughput - share your bottle drawing and we will confirm the exact configuration.
| Code Types Read | Laetus Pharmacode (single and two-track); alphanumeric batch, MFG and EXP by OCR/OCV; Code 39, Code 128, GS1-128, EAN/UPC, ITF-14; QR and GS1 DataMatrix; human-readable interpretation cross-check. |
|---|---|
| Verification Mode | Read-only, read-and-compare against the batch value, or full OCV character-by-character verification - selected per field in the recipe. |
| Barcode Grading | ISO/IEC 15415 (2D) and 15416 (1D) with per-parameter scoring and A-F grade trending over the batch. |
| Cameras | 1 to 4 per station. Basler area-scan 2 - 12 MP, monochrome or colour; dedicated Pharmacode readers where a fixed single-track read is all that is required. |
| Lighting | Strobed LED bar, coaxial or dome illumination selected by print method and substrate; red or infrared to suppress background artwork. IP65, 24 V, per-recipe intensity. |
| Inspection Speed | Up to 600 reads/min; typical read and verify time 4 - 15 ms depending on code type and image size. |
| Substrates | Carton board, coated and uncoated; leaflets and inserts; aluminium blister lidding foil; self-adhesive labels; PVC and Alu-Alu. |
| Fault Action | Per-defect choice of pack reject, line stop with batch hold, or log-only - configured in the recipe and lockable to a supervisor login. |
| Reject Mechanism | Pneumatic pusher or drop-flap, encoder-tracked, with reject confirmation sensor and lockable bin. Line stops on unconfirmed reject. |
| Control System | Siemens S7-1200 / S7-1500 PLC with 10" or 15" colour HMI; vision controller with recipe management, live statistics and reject image gallery. |
| Data & Reporting | Every read logged with batch, timestamp and verdict; barcode grade trend; CSV or PDF batch report; OPC UA or SQL push to plant systems on request. |
| Integration | Mounts on the cartoner, blister machine, leaflet feeder or labeller. Hardwired I/O, PROFINET, Ethernet/IP or Modbus TCP to the host machine PLC. |
| Material of Construction | SS304 frame, guards and enclosure; IP65 camera and light housings; GMP-compliant construction. |
| Power & Air | 0.4 - 1.5 kW at 230 V single phase or 415 V 3-phase; 6 bar air at approx. 50 - 120 NL/min where a reject is fitted. |
| Compliance | GMP construction; 21 CFR Part 11 software, US DSCSA and EU FMD serialisation support available. |

Code verification is rarely the only inspection on a regulated line. These are the stations it works with.
Tell us which codes you print, on what, and with which printer. We will image them, show you the read and the grade, and scope the station against a proven result rather than a specification sheet.
Written by our engineers to help you specify, validate and run this kind of machine. More in the Knowledge Center.