Vision - Fill Level & Liquid

Bottle Fill Level Inspection System

Underfill is a customer complaint and a legal metrology problem; overfill is money poured away every shift. MEF fill level inspection stations measure the liquid line in every container - clear, coloured, opaque or foaming - and reject out-of-tolerance packs at up to 600 per minute, while feeding the trend straight back to the filler.

MEF fill level inspection system using a backlight and camera to measure the liquid line in filled PET bottles on a conveyor
Backlit vision - the liquid meniscus becomes a sharp edge the camera can measure to sub-millimetre.
Up to 600/minSpeed
±0.5 mmAccuracy
X-ray optionOpaque Packs
To the fillerFeedback

Why Choose a MEF Fill Level Inspection System?

Checking a sample every half hour tells you a batch went wrong thirty minutes ago. Checking every bottle tells you the moment a nozzle starts to drift - which is the difference between an adjustment and a rework.

Sub-Millimetre Measurement

Against a diffused backlight the meniscus becomes a hard edge. The system measures the level to about ±0.5 mm and compares it to a tolerance band per SKU.

Opaque and Metal Packs Too

Where the container is opaque, foiled or metal, we use X-ray or gamma level sensing instead of vision. The same station, the same reject, a different sensor.

Feed the Result Back to the Filler

Level trend per filling head is pushed back to the filler, so a drifting nozzle is corrected automatically rather than discovered at the end of the batch.

Foam Handled Properly

Foaming products defeat a naive threshold. Recipes distinguish liquid line from foam head, with a settling distance after the filler chosen for your product.

Foreign Particle Detection

With the right optics the same station can find floating and suspended particles, glass fragments and fibres in clear liquids - a common pharma requirement.

Legal Metrology Evidence

Every reading is logged with batch and timestamp, giving you the continuous record that average-content and net-quantity compliance actually asks for.

Reject You Can Prove

Encoder-tracked to the arm and confirmed by a sensor. If the confirmation does not arrive, the line stops rather than passing the pack.

Retrofits Your Filler

Any make. The station needs conveyor space after the filler and a power connection, and interlocks over hardwired I/O or Ethernet.

Fill level inspection systemBottle fill level detectionUnderfill detectionOverfill inspectionLiquid level inspection machineVision fill level controlX-ray fill level inspectionGamma level detectionParticle inspection machineNet content verificationFill level inspection IndiaFiller feedback control

How Level Measurement Works

The station reads a level, compares it to a band, and does two things with the answer.

1SettleBottles travel a set distance after the filler so foam collapses and the level stabilises.
2BacklightA diffused backlight opposite the camera turns the liquid line into a sharp edge.
3MeasureThe level is measured against the neck ring or base datum, not the conveyor.
4RejectOut-of-band packs are tracked to the arm, pushed off and confirmed by sensor.
5Feed BackPer-head level trend goes to the filler so a drifting nozzle self-corrects.

Technical Specifications

Indicative figures for the standard build. Every machine is engineered to your container, product and throughput - share your bottle drawing and we will confirm the exact configuration.

Inspection ChecksUnderfill, overfill, empty or missing liquid, gross foam, and - with the particle option - floating or suspended foreign matter in clear liquids.
Sensing MethodVision with diffused backlight for clear and translucent containers; X-ray or gamma level sensing for opaque, foiled, metal or heavily decorated packs.
Cameras1 to 2 per station. Basler area-scan, 2 - 12 MP, monochrome with a red or infrared backlight to suppress label and product colour variation.
Measurement AccuracyApproximately ±0.5 mm on a stable container, referenced to the neck ring or base datum rather than the conveyor surface.
Inspection SpeedUp to 600 containers/min single lane; typical inspection time 5 - 12 ms per container.
Container Range20 mm to 130 mm diameter, 40 mm to 350 mm height, 5 ml to 5 litre, in PET, HDPE, glass or aluminium; round, square, oval and flat.
Tolerance SettingUpper and lower limits per SKU in millimetres or millilitres, set from the HMI and stored in the recipe with a supervisor lock.
Filler FeedbackPer-head level statistics returned to the filling machine over PROFINET or Ethernet/IP for automatic volume correction (optional).
Reject MechanismPneumatic pusher or drop-flap, encoder-tracked, with reject confirmation sensor and lockable bin. Line stops on unconfirmed reject.
Control SystemSiemens S7-1200 / S7-1500 PLC with 10" colour HMI; vision controller with recipe management, live level histogram and reject image gallery.
Data & ReportingLevel reading logged per container with batch and timestamp; histogram and per-head trend charts; CSV or PDF batch report export.
IntegrationStraddle-mounts over an existing conveyor or supplied with its own SS conveyor. Hardwired I/O, PROFINET, Ethernet/IP or Modbus TCP.
Material of ConstructionSS304 frame, guards and enclosure; IP65 camera and light housings; washdown execution available.
Power & Air0.5 - 1.5 kW at 230 V single phase or 415 V 3-phase; 6 bar air at approx. 50 - 100 NL/min for the reject.

Optional Features

  • Foreign particle inspection with container spin-and-stop for suspended matter in clear liquids
  • X-ray or gamma level sensing for opaque, metal, foiled or fully sleeved containers
  • Automatic filler feedback correcting volume per head from the measured trend
  • Checkweigher pairing so weight and level verdicts share one reject decision
  • Empty bottle inspection before the filler - base contamination, cracks and foreign objects
  • Combined station carrying fill level, cap and label cameras on one frame
  • Legal metrology reporting pack with average-content statistics per batch
  • 21 CFR Part 11 software with audit trail, e-signature and role-based access

Key Features

  • Every container measured, not a sample every half hour
  • Level referenced to the neck ring, so bottle height variation does not become a false reject
  • Foam and liquid distinguished by recipe rather than by a naive brightness threshold
  • Per-head histogram on the HMI - a drifting nozzle is obvious at a glance
  • Reject confirmed by sensor, with the line stopping if confirmation is missing
  • Continuous record of level by batch and timestamp for metrology and customer complaints
  • Works on any filler - the station is independent of the machine upstream
  • Sub-millimetre repeatability from proper backlighting rather than expensive optics
Layout drawing of the MEF fill level inspection station showing backlight, camera, trigger sensor, reject arm and reject bin
Camera opposite a diffused backlight, with the reject placed far enough downstream for clean tracking.

Industries & Applications

  • Pharmaceutical: oral liquids and syrups, vials and ampoules, eye and ear drops, dry-syrup diluent, plus particle inspection for injectables
  • Food & beverage: packaged drinking water, juices, carbonated drinks, edible oil, ghee, honey and sauces
  • Cosmetics & personal care: shampoo, lotion, serum and liquid soap where fill level is visible through the pack
  • Agrochemical & industrial: pesticides, lubricants, coolants and specialty chemicals with declared net content

FAQs: Fill Level Inspection System

How accurate is the level measurement?
Approximately ±0.5 mm on a stable container with proper backlighting. Converting that to millilitres depends on your bottle's cross-section at the fill line - in a narrow neck, half a millimetre is a very small volume; in a wide jar it is larger. We calculate the millilitre equivalent for your specific container during the feasibility study.
Will it work on opaque or fully sleeved bottles?
Not with vision - light has to reach the camera. For opaque, metal, foiled or fully shrink-sleeved packs we fit X-ray or gamma level sensing instead. Same frame, same reject mechanism, same HMI; only the sensor changes. Gamma systems carry regulatory requirements for the source, which we handle as part of the project.
How does it cope with foaming products?
Two ways. First, physically: the station is positioned far enough downstream of the filler for foam to collapse, and we calculate that distance from your product and line speed. Second, in the recipe: the liquid line and the foam head have different optical signatures under a diffused backlight, and the tool is configured to measure the former.
Can it detect particles in the liquid?
Yes, in clear liquids, with the particle option. The container is spun and stopped so the liquid keeps rotating while the glass or PET is still, and a high-speed sequence detects moving particles against a static background. This is a standard requirement for injectables and is a genuinely different optical setup from level checking - it is quoted separately.
Can it correct the filler automatically?
Yes, with the feedback option. Level statistics per filling head are pushed back over PROFINET or Ethernet/IP, and the filler adjusts that head's dose. On the MEF liquid filling machine this is a supported integration; on third-party fillers it depends on what their control system exposes.
Is a checkweigher better than fill level vision?
They answer different questions. A checkweigher measures total mass, which covers everything including product density variation, but it is slower and needs a weighing conveyor. Vision level inspection is faster, cheaper and detects the visual defect your customer will see. Lines with tight legal-metrology requirements often run both, sharing one reject.
Where exactly should the station sit?
After the filler and after the capper, if you can. Level readings are more stable once the pack is closed, and a single frame downstream of the capper can then carry cap inspection and level cameras together - one trigger, one controller, one reject, less conveyor.

Send us filled samples and your tolerance band

Twenty bottles at target level, plus your worst underfill and overfill, and we will show you the measured result under proper lighting before you commit to anything.