On this page
- What the rules cover
- Declarations required on the pack
- Maximum permissible error: how the table works
- Setting a checkweigher against the permissible error
- Giveaway economics: a worked example in ₹
- Verification and stamping of weighing instruments
- OIML R51: the international standard for checkweighers
- Frequently asked questions
- References
What the rules cover
In India, pre-packaged commodities for retail sale are governed by the Legal Metrology Act, 2009 and the Legal Metrology (Packaged Commodities) Rules, 2011, as amended. They are administered by the Department of Consumer Affairs and enforced by the state Legal Metrology departments. The Rules cover:
- what must be declared on the package, and how prominently;
- declaration of net quantity in standard units of weight, volume, length, area or number;
- the maximum permissible error in net quantity for individual packages, and how packages are sampled and judged;
- registration of manufacturers, packers and importers of pre-packaged commodities.
The Rules have been amended several times since 2011. Always work from the current consolidated text, available through the Department of Consumer Affairs and state Legal Metrology offices, not an old copy saved on a shared drive.
Declarations required on the pack
For a retail package, the Rules require declarations that typically include the following. Check the current text for your commodity, because some products have special provisions and packages for institutional or industrial consumers are treated differently.
- Name and complete address of the manufacturer, packer or importer (and country of origin for imported goods).
- Common or generic name of the commodity.
- Net quantity in the standard unit of weight or measure, or in number.
- Month and year of manufacture, and a best-before or use-by date where the product becomes unfit for use after a period.
- Retail sale price, as maximum retail price inclusive of all taxes.
- Unit sale price - the price per standard unit, such as per kg or per litre - added by recent amendments.
- Consumer care details: the person to contact for complaints, with address, telephone number and email.
The Rules also set minimum heights for the net quantity figures relative to the size of the principal display panel. On a line, most of these are printed on the film or carton by the converter; the batch-specific ones - date, sometimes price - are added by a coder, which a vision system can verify.
Maximum permissible error: how the table works
The Rules include a schedule of maximum permissible errors in net quantity. For each band of declared quantity it states how far below the declared quantity an individual package may fall. For packages declared by weight or volume, some bands express the error as a percentage of the declared quantity and others as a fixed amount in grams or millilitres. The fixed-amount bands smooth the steps between percentage bands, so the allowed error does not drop sharply when a pack size crosses a band boundary. Packages declared by length, area or number are treated separately.
For packages declared by weight or volume, Table I of the First Schedule to the Rules sets these limits (text as hosted by the Legal Metrology Department, Government of Nagaland - check the current notified version before relying on it):
| Declared quantity (g or ml) | Maximum permissible error | Example |
|---|---|---|
| Up to 50 | 9% of declared quantity | 20 g pack: 1.8 g |
| 50 to 100 | 4.5 g or ml | 100 g pack: 4.5 g |
| 100 to 200 | 4.5% of declared quantity | 200 g pack: 9 g |
| 200 to 300 | 9 g or ml | 250 g pack: 9 g |
| 300 to 500 | 3% of declared quantity | 500 g pack: 15 g |
| 500 to 1,000 | 15 g or ml | 1 kg pack: 15 g |
| 1,000 to 10,000 | 1.5% of declared quantity | 5 kg pack: 75 g |
| 10,000 to 15,000 | 150 g or ml | 15 kg pack: 150 g |
| More than 15,000 | 1% of declared quantity | 25 kg bag: 250 g |
Percentage values are rounded to the nearest 0.1 g or ml for declared quantities up to 1,000 g or ml, and to the next whole g or ml above that. Notice how the fixed-amount bands (4.5 g, 9 g, 15 g, 150 g) join the percentage bands so the allowance does not jump at a boundary.
We could not verify the current values against the official notified text, and the table has been subject to amendment. A wrong figure here could put your packs out of compliance. Take the value for your declared quantity from the current Rules, and record the source and date in your checkweigher settings file.
Three points are often misunderstood:
- It is an allowance, not a target. Filling to "declared minus permissible error" guarantees that a large share of packs will be short beyond the limit, because every filler scatters.
- It applies to individual packs. Inspectors sample packages from a lot, and the Rules set out how the lot is judged. Read the sampling provisions together with the error table.
- Overfill is not a compliance problem, it is a cost. Product given away above the declared quantity is money that never comes back.
Setting a checkweigher against the permissible error
A checkweigher weighs each pack gross - product plus packaging - and rejects any below a lower limit. Setting that limit well means combining four sources of variation:
| Source | What it is | How to handle it |
|---|---|---|
| Fill scatter | Pack-to-pack variation from the filler or weigher | Measure its standard deviation on the line; reduce it at the filler |
| Tare variation | Film, pouch or bottle weight varies | Weigh a sample of empty packs from each packaging lot; set the limit on the heavier side |
| Checkweigher error | Dynamic weighing at line speed is less precise than a static scale | Test with known test packs at production speed |
| Moisture loss | Bakery goods, soap, some fresh foods lose weight before sale | Add a margin so packs are still compliant at the shelf |
Two decisions follow. First, the lower reject limit: many brand owners reject anything below the declared quantity; others set it below declared quantity but inside the permissible error, with a margin. That is a legal and brand decision, not a machine setting. Second, the target mean the filler runs at:
Here z is how many standard deviations of safety you want; at z = 3, roughly one pack in a thousand falls below the limit if the weights follow a normal distribution, and the checkweigher removes it.
Giveaway economics: a worked example in ₹
An illustrative 1 kg atta line, 2 million packs a year, product cost ₹35/kg, with a plant policy of no pack below 1,000 g net and z = 3.
| Illustrative figure | Before | After servo auger + feedback |
|---|---|---|
| σ fill | 4.0 g | 2.0 g |
| σ tare / σ checkweigher | 0.5 g / 1.0 g | 0.5 g / 1.0 g |
| Combined σ | 4.15 g | 2.29 g |
| Target mean (1,000 + 3σ) | 1,012.5 g | 1,006.9 g |
| Giveaway per pack | 12.5 g | 6.9 g |
The improvement is about 5.6 g a pack. Over 2 million packs that is about 11,200 kg of atta - roughly ₹3.9 lakh a year at ₹35/kg. For a product at ₹300/kg, such as a spice blend or dry fruit, the same grams are worth nearly nine times as much.
Notice what did not help much: the checkweigher's own error and the tare variation are small next to fill scatter. Money spent on a better auger filler or multihead weigher, with checkweigher feedback holding the mean, usually earns more than money spent on a faster checkweigher. See choosing the right doser.
Verification and stamping of weighing instruments
Under the Legal Metrology Act, weights and measures used in transactions or for protection must be of an approved model and must be verified and stamped by the Legal Metrology department, with re-verification at the intervals the rules set. In a packing plant, that applies most clearly to the scales used to establish and check net quantity.
- Keep the QC reference balance used for net-quantity checks verified and stamped, and its certificate on file.
- Ask your local Legal Metrology office whether your in-line checkweigher, as you use it, needs verification. Practice depends on how its results are used.
- Check the checkweigher at every shift start with test packs of known weight, at production speed, and log the result.
- Re-check after any change of product, packaging lot or speed, and after maintenance.
- Check the metal detector with test pieces at the same time. See metal detector sensitivity.
OIML R51: the international standard for checkweighers
OIML R 51 is the International Organisation of Legal Metrology's recommendation for automatic catchweighing instruments - machines that weigh discrete loads, such as packs, automatically as they pass. It sets metrological requirements and test methods. Instruments are grouped into categories: X for instruments used to check prepackages against quantity requirements, and Y for other uses such as weigh-labelling and grading, each with its own accuracy classes.
For a buyer, R 51 matters in two ways. A checkweigher model tested and certified to it has had its dynamic accuracy tested by a third party at defined speeds and loads, not just stated in a brochure. And its accuracy classes give you a common language for comparing quotations. When you buy, ask for the accuracy at your pack weight and line speed, stated as a standard deviation, and for any OIML or national type-approval certificates the model holds. Our checkweigher and metal detector systems are specified to your pack range and speed.
Frequently asked questions
What is the permissible error for net quantity under Legal Metrology rules?
What must be declared on a packaged commodity in India?
How should I set my checkweigher reject limit?
Does my checkweigher need Legal Metrology stamping?
What is OIML R51?
References
- Legal Metrology (Packaged Commodities) Rules, 2011 - text hosted by the Legal Metrology Department, Government of Nagaland
- Legal Metrology (Packaged Commodities) Rules, 2011 - UNEP LEAP legislation record
- OIML R 51-1: Automatic catchweighing instruments - Metrological and technical requirements (oiml.org)
Regulatory text changes. Always check the current version of a regulation before relying on it; this article reflects our reading as of 29 Sep 2026 and is not legal advice.