Troubleshooting

Metal Detector Sensitivity and Test Pieces: A Practical Guide

A metal detector is only as good as its weakest point: the centre of the aperture, a wet product, a stainless fragment - or a reject system nobody checks. Here is how sensitivity really works and how to verify it.

By MEF Automation Engineering TeamUpdated 8 min read
In short
  • Test with ferrous, non-ferrous and 316 stainless pieces. Stainless is the hardest to detect, especially in wet or salty products.
  • Sensitivity is lowest at the centre of the aperture, so that is where the test piece should pass. A smaller aperture gives better sensitivity.
  • Wet, salty and conductive products produce their own signal. Frequency choice and product learning decide how much sensitivity you keep.
  • A detection is worthless if the pack is not rejected. Verify the reject, not just the alarm, and design the system to fail safe.
  • Auditors look for a verification record every time: time, product, test pieces, result, reject confirmed, and action taken on failure.
On this page
  1. Symptom, cause, check, fix: the quick table
  2. Ferrous, non-ferrous and stainless: why stainless is hardest
  3. Aperture, product effect, orientation and frequency
  4. Verifying sensitivity with test pieces
  5. Reject confirmation and fail-safe design
  6. Detector types and audit records
  7. Shift checklist, prevention and when to call service
  8. Frequently asked questions

Symptom, cause, check, fix: the quick table

A metal detector problem is a food safety problem first. If a verification test fails, stop, quarantine product back to the last good test, and only then start troubleshooting.

SymptomLikely causesWhat to checkFix
Test piece not detectedWrong product programme; product effect re-learned badly; settings changed; detector faultSelected programme; settings log; test piece positionSelect and re-learn programme; restore settings; call service if it persists
Detected but not rejectedReject timing off after speed change; low air; reject device faultAir pressure; timing photocell; belt speedRe-time reject; restore air; repair device
Rising false rejectsProduct temperature, salt or moisture changed; sensitivity set beyond stable limitProduct condition; recent setting changesRe-learn product; set sensitivity at a stable margin
Random false rejectsVibration; electrical noise; loose metal touching near the aperture; another detector close byMetal-free zone; loose guards and rollers; nearby drivesSecure parts; clear the zone; separate frequencies
Stainless fails, ferrous passesFrequency unsuitable; test size unrealistic for aperture and productFrequency setting; aperture sizeAdjust frequency or use multi-frequency; review specification
Rejected packs back in good productBin left open; no reject confirmation; bin overflowingBin lock, bin-full sensorLock bin; add confirmation and bin-full stop

Ferrous, non-ferrous and stainless: why stainless is hardest

A balanced-coil detector has a transmitter coil and two receiver coils. Metal passing through disturbs the field and unbalances the receivers. How much depends on whether the metal is magnetic, conductive, or both.

Test piecePropertiesDetectability
Ferrous (chrome steel)Magnetic and conductiveEasiest; strong signal
Non-ferrous (brass, aluminium)Conductive, not magneticClose to ferrous in dry products; harder in wet ones
Stainless steel 316Effectively non-magnetic; poor conductorHardest - typically needs a noticeably larger sphere than ferrous for the same detection, and larger still in wet products

Most food and pharma equipment is stainless steel, so the fragments you are most likely to find are the hardest to detect. That is why stainless test pieces, normally grade 316, are part of every serious verification routine. Test pieces are usually spheres, specified by diameter in mm, because a sphere gives the same signal in any orientation. Use certified, individually identified pieces.

Aperture, product effect, orientation and frequency

Aperture and the centre effect

Sensitivity depends mostly on aperture size - especially the smaller opening dimension. Choose the smallest aperture that passes the pack with sensible clearance. Inside the aperture, the signal is weakest at the geometric centre, furthest from the coils, and strongest near the walls. Pass the test piece through the centre (or the least sensitive position for that pack) to test the worst case. Keep the manufacturer's metal-free zone around the aperture clear of moving metal, loose guards and tools.

Product effect

Wet, salty or conductive products - meat, cheese, pickles, sauces, bread, frozen products that start to thaw - generate a signal of their own. The detector learns the product's signal and suppresses it, but that costs some sensitivity, and when temperature, salt or pack size changes, false rejects follow. Dry products such as flour, sugar, biscuits and tablets have little product effect. Aluminium foil packs or trays block a normal detector; they need a ferrous-in-foil detector, X-ray, or inspection before packing.

Orientation of wires

Spheres do not show the orientation effect, but real contaminants are often wires or swarf. In general, ferrous wire is easiest to detect lying along the direction of travel, while non-ferrous and stainless wires are easiest lying across it. A wire much longer than the test sphere's diameter can still be missed in its worst orientation.

Frequency

Higher frequencies are more sensitive to stainless and small non-ferrous pieces in dry products, but increase product effect in wet ones. Lower frequencies suit wet, conductive products. Multi-frequency detectors combine them to keep stainless sensitivity while suppressing product signal. Frequency is normally stored per product programme.

Verifying sensitivity with test pieces

How often you test should follow your HACCP risk assessment and customer requirements. General practice is to verify:

  • at the start of production or each shift;
  • after every product changeover or programme change;
  • after maintenance, cleaning or any setting change;
  • at regular intervals during production - commonly hourly;
  • at the end of the run.
  1. Take the certified ferrous, non-ferrous and stainless pieces specified for this product and line.
  2. Place each in or on a pack so it passes through the centre of the aperture.
  3. Run at normal production speed, not slowed down.
  4. Confirm the alarm and that the test pack lands in the reject bin; run it between good packs to check only the contaminated pack is rejected.
  5. Record the result. If any test fails, stop the line, quarantine all product since the last successful test, correct the fault, retest, and re-inspect the quarantined product.
Common mistakes

Testing at slow speed, passing the test piece near the aperture wall, holding the test pack by hand through the aperture, or checking the alarm without checking the reject. Each makes the test pass while the line would miss real metal.

Reject confirmation and fail-safe design

A fail-safe detector system assumes something will go wrong and makes sure contaminated product cannot reach a customer when it does. Retailer codes of practice and customer audits commonly expect features such as:

  • An automatic reject device (air blast, pusher, retracting band or diverter) suited to the pack.
  • Reject confirmation - a sensor proving the pack left the line, with a stop if it did not.
  • A bin-full sensor and a lockable reject bin, key held by QA.
  • Low air pressure monitoring on pneumatic rejects.
  • Line stop or alarm on detector fault or loss of balance.
  • Guarding between detector and reject so packs cannot be removed by hand.
  • Password-protected sensitivity settings with a change log.

When combined with a checkweigher on one frame, each function needs its own reject verification or clearly separated reject bins - see our checkweigher and metal detector systems, and Legal Metrology and checkweighers for the weighing side.

Detector types and audit records

TypeWhere it fitsNote
Conveyor (tunnel)Packed products, cartons, traysAperture sized to the pack
Throat (gravity)Free-falling powders, snacks and granules, e.g. between a weigher and a pouch or jar fillerSmall aperture gives high sensitivity; inspects before metallised film
PipelinePumped liquids, pastes, slurriesProduct and pipe matched to aperture
Pharma tablet / capsuleAfter tablet press or dedusterVery small aperture, fast reject flap; audit trail often required

Records. Schemes such as BRCGS and FSSC 22000 expect foreign-body controls to be justified by hazard analysis, verified and recorded. Keep, for every check: date, time, line, product and programme, test piece identities and sizes, result, reject confirmed, operator, and action on failure. Add test piece certificates, periodic performance checks by a competent engineer, settings change records, and a log of real metal finds from the reject bin so you can trace them to their source. On pharma lines, electronic records follow the same rules as any other - see 21 CFR Part 11 for packaging machines.

Shift checklist, prevention and when to call service

  • Confirm the correct product programme is selected.
  • Verify with all three test pieces at start, changeover, set intervals and end.
  • Check the reject bin is locked, and test the bin-full sensor.
  • Check the air pressure gauge on the reject.
  • Inspect the belt and metal-free zone for loose metal, tools and damage.
  • Review false-reject counts; investigate any rise.
  • Inspect reject bin contents and log real metal finds.

Prevention means stopping metal at source - sieve and magnet checks, blade and screen inspections - and keeping the detector system maintained and its records honest.

Call service when verification keeps failing after re-learning the programme, the detector shows balance or fault alarms, false rejects persist, a new high-product-effect product is introduced, or the unit is moved. Periodic performance checks and spare reject parts can be covered by an AMC and the spare parts programme.

Frequently asked questions

Why is stainless steel the hardest metal to detect?
Grades such as 316 are effectively non-magnetic and poor electrical conductors, so they disturb the detector's field far less than ferrous metal. The effect is worse in wet or salty products, where the detector must suppress the product's own signal. Stainless test pieces therefore usually need to be larger than ferrous ones for reliable detection.
Where should the test piece be placed when testing a metal detector?
Pass it through the geometric centre of the aperture, where sensitivity is lowest, placed in or on a real pack and run at normal production speed. Testing near the aperture walls or at slow speed gives a false sense of security. Confirm both the detection and that the test pack actually goes into the reject bin.
How often should a metal detector be tested?
Your HACCP risk assessment and customer requirements decide. General practice is at start-up or each shift, after every product changeover or setting change, after maintenance, at regular intervals during production - commonly hourly - and at the end of the run. If a test fails, quarantine everything produced since the last successful test.
What causes metal detector false rejects?
Common causes are changes in product effect (temperature, salt, moisture, pack size), sensitivity set beyond a stable margin, vibration, electrical interference, loose metal touching near the aperture, and other detectors installed close by. Re-learn the product, check the metal-free zone and secure loose parts before reducing sensitivity.
What size test pieces should a food metal detector use?
There is no single size. It depends on the product, pack, aperture size and your customers' or retailers' specifications. The right approach is to set sizes through your hazard analysis and prove them with trials on the actual product, at production speed, with ferrous, non-ferrous and stainless pieces.

Need to prove your metal detection?