On this page
- Symptom, cause, check, fix: the quick table
- Ferrous, non-ferrous and stainless: why stainless is hardest
- Aperture, product effect, orientation and frequency
- Verifying sensitivity with test pieces
- Reject confirmation and fail-safe design
- Detector types and audit records
- Shift checklist, prevention and when to call service
- Frequently asked questions
Symptom, cause, check, fix: the quick table
A metal detector problem is a food safety problem first. If a verification test fails, stop, quarantine product back to the last good test, and only then start troubleshooting.
| Symptom | Likely causes | What to check | Fix |
|---|---|---|---|
| Test piece not detected | Wrong product programme; product effect re-learned badly; settings changed; detector fault | Selected programme; settings log; test piece position | Select and re-learn programme; restore settings; call service if it persists |
| Detected but not rejected | Reject timing off after speed change; low air; reject device fault | Air pressure; timing photocell; belt speed | Re-time reject; restore air; repair device |
| Rising false rejects | Product temperature, salt or moisture changed; sensitivity set beyond stable limit | Product condition; recent setting changes | Re-learn product; set sensitivity at a stable margin |
| Random false rejects | Vibration; electrical noise; loose metal touching near the aperture; another detector close by | Metal-free zone; loose guards and rollers; nearby drives | Secure parts; clear the zone; separate frequencies |
| Stainless fails, ferrous passes | Frequency unsuitable; test size unrealistic for aperture and product | Frequency setting; aperture size | Adjust frequency or use multi-frequency; review specification |
| Rejected packs back in good product | Bin left open; no reject confirmation; bin overflowing | Bin lock, bin-full sensor | Lock bin; add confirmation and bin-full stop |
Ferrous, non-ferrous and stainless: why stainless is hardest
A balanced-coil detector has a transmitter coil and two receiver coils. Metal passing through disturbs the field and unbalances the receivers. How much depends on whether the metal is magnetic, conductive, or both.
| Test piece | Properties | Detectability |
|---|---|---|
| Ferrous (chrome steel) | Magnetic and conductive | Easiest; strong signal |
| Non-ferrous (brass, aluminium) | Conductive, not magnetic | Close to ferrous in dry products; harder in wet ones |
| Stainless steel 316 | Effectively non-magnetic; poor conductor | Hardest - typically needs a noticeably larger sphere than ferrous for the same detection, and larger still in wet products |
Most food and pharma equipment is stainless steel, so the fragments you are most likely to find are the hardest to detect. That is why stainless test pieces, normally grade 316, are part of every serious verification routine. Test pieces are usually spheres, specified by diameter in mm, because a sphere gives the same signal in any orientation. Use certified, individually identified pieces.
Aperture, product effect, orientation and frequency
Aperture and the centre effect
Sensitivity depends mostly on aperture size - especially the smaller opening dimension. Choose the smallest aperture that passes the pack with sensible clearance. Inside the aperture, the signal is weakest at the geometric centre, furthest from the coils, and strongest near the walls. Pass the test piece through the centre (or the least sensitive position for that pack) to test the worst case. Keep the manufacturer's metal-free zone around the aperture clear of moving metal, loose guards and tools.
Product effect
Wet, salty or conductive products - meat, cheese, pickles, sauces, bread, frozen products that start to thaw - generate a signal of their own. The detector learns the product's signal and suppresses it, but that costs some sensitivity, and when temperature, salt or pack size changes, false rejects follow. Dry products such as flour, sugar, biscuits and tablets have little product effect. Aluminium foil packs or trays block a normal detector; they need a ferrous-in-foil detector, X-ray, or inspection before packing.
Orientation of wires
Spheres do not show the orientation effect, but real contaminants are often wires or swarf. In general, ferrous wire is easiest to detect lying along the direction of travel, while non-ferrous and stainless wires are easiest lying across it. A wire much longer than the test sphere's diameter can still be missed in its worst orientation.
Frequency
Higher frequencies are more sensitive to stainless and small non-ferrous pieces in dry products, but increase product effect in wet ones. Lower frequencies suit wet, conductive products. Multi-frequency detectors combine them to keep stainless sensitivity while suppressing product signal. Frequency is normally stored per product programme.
Verifying sensitivity with test pieces
How often you test should follow your HACCP risk assessment and customer requirements. General practice is to verify:
- at the start of production or each shift;
- after every product changeover or programme change;
- after maintenance, cleaning or any setting change;
- at regular intervals during production - commonly hourly;
- at the end of the run.
- Take the certified ferrous, non-ferrous and stainless pieces specified for this product and line.
- Place each in or on a pack so it passes through the centre of the aperture.
- Run at normal production speed, not slowed down.
- Confirm the alarm and that the test pack lands in the reject bin; run it between good packs to check only the contaminated pack is rejected.
- Record the result. If any test fails, stop the line, quarantine all product since the last successful test, correct the fault, retest, and re-inspect the quarantined product.
Testing at slow speed, passing the test piece near the aperture wall, holding the test pack by hand through the aperture, or checking the alarm without checking the reject. Each makes the test pass while the line would miss real metal.
Reject confirmation and fail-safe design
A fail-safe detector system assumes something will go wrong and makes sure contaminated product cannot reach a customer when it does. Retailer codes of practice and customer audits commonly expect features such as:
- An automatic reject device (air blast, pusher, retracting band or diverter) suited to the pack.
- Reject confirmation - a sensor proving the pack left the line, with a stop if it did not.
- A bin-full sensor and a lockable reject bin, key held by QA.
- Low air pressure monitoring on pneumatic rejects.
- Line stop or alarm on detector fault or loss of balance.
- Guarding between detector and reject so packs cannot be removed by hand.
- Password-protected sensitivity settings with a change log.
When combined with a checkweigher on one frame, each function needs its own reject verification or clearly separated reject bins - see our checkweigher and metal detector systems, and Legal Metrology and checkweighers for the weighing side.
Detector types and audit records
| Type | Where it fits | Note |
|---|---|---|
| Conveyor (tunnel) | Packed products, cartons, trays | Aperture sized to the pack |
| Throat (gravity) | Free-falling powders, snacks and granules, e.g. between a weigher and a pouch or jar filler | Small aperture gives high sensitivity; inspects before metallised film |
| Pipeline | Pumped liquids, pastes, slurries | Product and pipe matched to aperture |
| Pharma tablet / capsule | After tablet press or deduster | Very small aperture, fast reject flap; audit trail often required |
Records. Schemes such as BRCGS and FSSC 22000 expect foreign-body controls to be justified by hazard analysis, verified and recorded. Keep, for every check: date, time, line, product and programme, test piece identities and sizes, result, reject confirmed, operator, and action on failure. Add test piece certificates, periodic performance checks by a competent engineer, settings change records, and a log of real metal finds from the reject bin so you can trace them to their source. On pharma lines, electronic records follow the same rules as any other - see 21 CFR Part 11 for packaging machines.
Shift checklist, prevention and when to call service
- Confirm the correct product programme is selected.
- Verify with all three test pieces at start, changeover, set intervals and end.
- Check the reject bin is locked, and test the bin-full sensor.
- Check the air pressure gauge on the reject.
- Inspect the belt and metal-free zone for loose metal, tools and damage.
- Review false-reject counts; investigate any rise.
- Inspect reject bin contents and log real metal finds.
Prevention means stopping metal at source - sieve and magnet checks, blade and screen inspections - and keeping the detector system maintained and its records honest.
Call service when verification keeps failing after re-learning the programme, the detector shows balance or fault alarms, false rejects persist, a new high-product-effect product is introduced, or the unit is moved. Periodic performance checks and spare reject parts can be covered by an AMC and the spare parts programme.