A cocked cap is a leaking pack, a returned consignment and a complaint file. MEF cap inspection stations photograph every closure as it leaves the capper and check seating, height, tilt, colour, tamper band and induction seal - rejecting bad packs at up to 600 bottles per minute, with the picture stored to prove it.

Cap defects are the most common source of field leakage, and almost all of them are invisible to a human at line speed. They are, however, very visible to a correctly lit camera.
A side camera against a backlight turns the cap silhouette into a measurement. Tilt from about 1.5 degrees and height deviation of under a millimetre become numbers, not opinions.
Missing cap, cocked or cross-threaded, high cap, wrong cap type or colour, damaged or deformed closure, and missing or broken tamper-evident band.
With the right illumination angle the system confirms the foil seal is present and correctly bonded, catching the packs an induction tunnel missed.
Run alongside a servo capper and you have both the applied torque and a photograph of the result on every bottle - the combination that actually ends leakage complaints.
Verdicts are encoder-tracked to the reject arm and confirmed by a sensor. No confirmation, no line - a suspect pack cannot quietly rejoin good stock.
Colour and diameter checks catch the classic changeover error - the previous SKU's closures still in the sorter bowl at the start of a new batch.
Teach a new closure by running samples. Recipes hold camera, lighting and tolerance settings per SKU, protected behind a supervisor login.
Straddles the discharge conveyor after your existing capper - ours or anyone's - and interlocks over hardwired I/O or Ethernet.
Two views cover every closure failure mode that causes a leak or a recall.
Indicative figures for the standard build. Every machine is engineered to your container, product and throughput - share your bottle drawing and we will confirm the exact configuration.
| Inspection Checks | Missing cap; cocked, tilted or cross-threaded cap; high cap; wrong cap type, colour or diameter; damaged or deformed closure; missing or broken tamper-evident band; induction seal presence and bond. |
|---|---|
| Cameras | 1 to 3 per station - overhead area-scan plus one or two side cameras. Basler 2 - 12 MP, colour or monochrome, with telecentric or fixed-focus optics. |
| Lighting | Strobed LED: ring or dome light overhead for the cap face, backlight for the side silhouette, low-angle or coaxial for foil seal verification. IP65, 24 V, intensity set per recipe. |
| Inspection Speed | Up to 600 bottles/min single lane; typical inspection time 6 - 15 ms per bottle. |
| Tilt Sensitivity | Detects cap tilt from approximately 1.5 degrees; cap height deviation from approximately 0.5 mm, subject to bottle stability and neck finish. |
| Container Range | 20 mm to 130 mm bottle diameter, 40 mm to 350 mm height; cap diameters 18 mm to 120 mm in PET, HDPE, glass or aluminium. |
| Reject Mechanism | Pneumatic pusher or air blast, encoder-tracked, with reject confirmation sensor and lockable bin. Line stops on unconfirmed reject. |
| Control System | Siemens S7-1200 / S7-1500 PLC with 10" colour HMI; vision controller with recipe management, live reject statistics and reject image gallery. |
| Data & Reporting | Counts inspected, passed and rejected by defect type; batch report export as CSV or PDF; reject images stored with batch, timestamp and reason code. |
| Integration | Straddle-mounts over an existing conveyor or supplied with its own SS conveyor. Hardwired I/O, PROFINET, Ethernet/IP or Modbus TCP to your line PLC. |
| Material of Construction | SS304 frame, guards and enclosure; IP65 camera and light housings; washdown execution available. |
| Power Requirement | 0.5 - 1.2 kW; 230 V single phase or 415 V, 3-phase, 50 Hz. |
| Compressed Air | 6 bar clean dry air, approx. 50 - 100 NL/min for the reject actuator. |
| Compliance | GMP construction; 21 CFR Part 11 software with audit trail and e-signature available. |

Cap inspection normally sits immediately after the capper. These are the stations around it.
We will image them under proper lighting, show you exactly what is detectable and what is marginal, and quote against a proven result rather than an assumption.
Written by our engineers to help you specify, validate and run this kind of machine. More in the Knowledge Center.