Vision - Cap & Closure

Bottle Cap Inspection System

A cocked cap is a leaking pack, a returned consignment and a complaint file. MEF cap inspection stations photograph every closure as it leaves the capper and check seating, height, tilt, colour, tamper band and induction seal - rejecting bad packs at up to 600 bottles per minute, with the picture stored to prove it.

MEF cap inspection system with overhead and side cameras checking bottle closures for cocked and missing caps on a conveyor
Combined top and side view - the top camera finds missing and wrong caps, the side camera finds tilt and height.
Up to 600/minSpeed
From 1.5°Tilt Detection
1 - 3Cameras
<0.1%False Reject

Why Choose a MEF Cap Inspection System?

Cap defects are the most common source of field leakage, and almost all of them are invisible to a human at line speed. They are, however, very visible to a correctly lit camera.

Height and Tilt, Measured

A side camera against a backlight turns the cap silhouette into a measurement. Tilt from about 1.5 degrees and height deviation of under a millimetre become numbers, not opinions.

Every Closure Failure Mode

Missing cap, cocked or cross-threaded, high cap, wrong cap type or colour, damaged or deformed closure, and missing or broken tamper-evident band.

Induction Seal Verification

With the right illumination angle the system confirms the foil seal is present and correctly bonded, catching the packs an induction tunnel missed.

Pairs With Torque Data

Run alongside a servo capper and you have both the applied torque and a photograph of the result on every bottle - the combination that actually ends leakage complaints.

Reject You Can Prove

Verdicts are encoder-tracked to the reject arm and confirmed by a sensor. No confirmation, no line - a suspect pack cannot quietly rejoin good stock.

Wrong Cap, Wrong SKU

Colour and diameter checks catch the classic changeover error - the previous SKU's closures still in the sorter bowl at the start of a new batch.

New Cap in Minutes

Teach a new closure by running samples. Recipes hold camera, lighting and tolerance settings per SKU, protected behind a supervisor login.

Bolts Onto Your Line

Straddles the discharge conveyor after your existing capper - ours or anyone's - and interlocks over hardwired I/O or Ethernet.

Cap inspection systemBottle cap inspectionCocked cap detectionMissing cap detectionClosure inspection systemCap height inspectionInduction seal inspectionTamper evident band inspectionCap colour verificationVision cap inspection machineCap inspection IndiaLeak prevention inspection

What the Cameras Check

Two views cover every closure failure mode that causes a leak or a recall.

1Top ViewCap present, correct type, correct colour, correct diameter, no gross damage.
2Side SilhouetteCap height against the neck ring, and tilt angle measured off the backlit outline.
3Seal CheckInduction foil presence and bond, using a low-angle or coaxial light.
4Band CheckTamper-evident band present, intact and not pre-broken.
5Verdict & RejectEncoder-tracked to the arm, pushed off, sensor-confirmed, image stored.

Technical Specifications

Indicative figures for the standard build. Every machine is engineered to your container, product and throughput - share your bottle drawing and we will confirm the exact configuration.

Inspection ChecksMissing cap; cocked, tilted or cross-threaded cap; high cap; wrong cap type, colour or diameter; damaged or deformed closure; missing or broken tamper-evident band; induction seal presence and bond.
Cameras1 to 3 per station - overhead area-scan plus one or two side cameras. Basler 2 - 12 MP, colour or monochrome, with telecentric or fixed-focus optics.
LightingStrobed LED: ring or dome light overhead for the cap face, backlight for the side silhouette, low-angle or coaxial for foil seal verification. IP65, 24 V, intensity set per recipe.
Inspection SpeedUp to 600 bottles/min single lane; typical inspection time 6 - 15 ms per bottle.
Tilt SensitivityDetects cap tilt from approximately 1.5 degrees; cap height deviation from approximately 0.5 mm, subject to bottle stability and neck finish.
Container Range20 mm to 130 mm bottle diameter, 40 mm to 350 mm height; cap diameters 18 mm to 120 mm in PET, HDPE, glass or aluminium.
Reject MechanismPneumatic pusher or air blast, encoder-tracked, with reject confirmation sensor and lockable bin. Line stops on unconfirmed reject.
Control SystemSiemens S7-1200 / S7-1500 PLC with 10" colour HMI; vision controller with recipe management, live reject statistics and reject image gallery.
Data & ReportingCounts inspected, passed and rejected by defect type; batch report export as CSV or PDF; reject images stored with batch, timestamp and reason code.
IntegrationStraddle-mounts over an existing conveyor or supplied with its own SS conveyor. Hardwired I/O, PROFINET, Ethernet/IP or Modbus TCP to your line PLC.
Material of ConstructionSS304 frame, guards and enclosure; IP65 camera and light housings; washdown execution available.
Power Requirement0.5 - 1.2 kW; 230 V single phase or 415 V, 3-phase, 50 Hz.
Compressed Air6 bar clean dry air, approx. 50 - 100 NL/min for the reject actuator.
ComplianceGMP construction; 21 CFR Part 11 software with audit trail and e-signature available.

Optional Features

  • Neck and thread inspection for chipped glass finish or flashed plastic threads before capping
  • Cap orientation check for flip-tops, sports caps and printed closures that must face the label
  • Torque data correlation linking each image to the servo capper's applied-torque record
  • Trigger and pump dip-tube presence and orientation verification
  • Deep-learning classifier for cosmetic closure defects that rule-based tools cannot hold
  • Combined station carrying cap, fill level and label inspection on one frame
  • All-image storage mode for validation and process-capability studies
  • 21 CFR Part 11 software with audit trail, e-signature and role-based access

Key Features

  • Backlit side view turns cap tilt and height into a measurement instead of a judgement
  • Catches the changeover error - wrong colour or wrong diameter caps from the previous SKU
  • Reject confirmed by sensor, with the line stopping if confirmation does not arrive
  • Image of every reject with batch number and reason code for your quality record
  • Reject-rate trending on the HMI so capper drift is visible long before it becomes scrap
  • Recipe per SKU, taught from good and bad samples by your own operators
  • Retrofits any capper - the station only needs conveyor space and a power connection
  • IP65 optics that survive a washdown area rather than needing to be removed for cleaning
Layout drawing of the MEF cap inspection station showing camera positions, ring light, trigger sensor and pneumatic reject
A side camera against a backlight is what makes a two-degree cap tilt measurable rather than merely visible.

Industries & Applications

  • Pharmaceutical: CRC closures on syrup and oral liquid bottles, induction seal verification, tamper-band integrity, dry-syrup and vial caps
  • Food & beverage: packaged drinking water, juice and beverage closures, ROPP caps on glass, edible oil and sauce packs
  • Cosmetics & personal care: lotion pumps, trigger sprays, flip-top and disc-top caps where orientation and shade matter
  • Agrochemical & industrial: child-resistant closures on hazardous packs, induction-sealed lubricant and chemical bottles

FAQs: Cap Inspection System

How small a cap tilt can it actually detect?
With a side camera against a backlight, tilt from approximately 1.5 degrees and cap height deviation from about 0.5 mm. The limiting factor is usually not the camera - it is how stable your bottle is on the conveyor at the inspection point. A guided or gripper-belt section through the station is sometimes the cheapest way to improve detection.
Can it check the induction foil seal?
Yes, with the correct illumination. A low-angle or coaxial light makes the difference between a properly bonded foil, a partially bonded one and a missing seal visible through the closure. This is a common addition on pharma and lubricant lines that already run an induction tunnel but have no verification after it.
Will it catch the wrong cap after a changeover?
Yes - that is one of the highest-value checks it performs. Diameter, colour and cap-face pattern are all part of the recipe, so closures left in the sorter bowl from the previous SKU are rejected as soon as they appear rather than being found by a customer.
What is the false reject rate?
Typically well under 0.1% for well-defined closure defects with correctly designed lighting. Cosmetic defects such as faint scuffs are harder and we will say so rather than promise a number. We prove the actual rate on your samples during the feasibility study before quoting.
Does it work with our existing capping machine?
Yes. The station is independent of the capper and mounts on the discharge conveyor, so it works with any make. If you run the MEF linear capping machine, we go one step further and link each image to that bottle's applied-torque record.
Can it be combined with fill level inspection?
Yes, and it usually should be. One frame can carry cap and fill level cameras sharing a single trigger, controller and reject - which is cheaper and takes less conveyor space than two separate stations.
How do we add a new bottle or cap?
Run good samples and known-bad samples through the station and save the result as a named recipe. Camera, lighting and tolerance settings are all stored in it. Recipes can be locked to a supervisor login for validated lines.

Send us twenty bottles and your worst defects

We will image them under proper lighting, show you exactly what is detectable and what is marginal, and quote against a proven result rather than an assumption.