Pharma Secondary Packaging - Vials

Vial Pick and Place into Blister Trays

MEF vial pick and place systems take labelled injection vials from the line, place them into thermoformed blister trays and hand every full tray to the cartoner. A robot with a multi-pick head replaces the manual tray-filling table, a camera checks every pocket before the tray moves on, and the counts feed your batch reconciliation.

Robot with a multi-pick head placing glass injection vials into clear PVC blister trays on an indexing conveyor
Multi-pick robot head placing a row of 10 ml vials into a 5-pocket PVC blister tray.
2 - 50 mlVial Range
1 to 10 pocketsTray Patterns
60 - 150 vials/minIndicative Output
Every tray, by visionPocket Check

Why Choose MEF for Vial Tray Loading?

On most Indian injectable lines, vials still go into their blister trays by hand after labelling. It is the one manual step between two automatic machines - and the step where miscounts, empty pockets and glass breakage start.

Gentle Handling of Glass

Vials are picked by vacuum cups on the flip-off seal or by soft fingers around the body. Glass-contact parts are food-grade polymer, and the head slows down before it enters the pocket, so vials are placed rather than dropped.

Any Tray Pattern

Single, 2, 5 and 10-pocket trays - in a row or two rows - are handled by changing the recipe and the format parts. The pick head lifts a full row at a time, which is how the robot keeps pace with the labeller.

Every Pocket Checked

A camera over the filled tray confirms each pocket holds one upright vial with its seal in place. A tray with an empty pocket or a tilted vial is pushed to the reject lane, never to the cartoner.

Counts for Batch Reconciliation

The HMI counts vials in, vials placed, trays completed and rejects for each batch, so the packing record reconciles against the filling count without a manual tally at the tray table.

Fast Size Changeover

Feed screw, collating nest, pick head and tray guides are colour-coded format parts. The operator swaps them and selects the recipe; robot positions and speeds for that vial and tray are stored in it.

One Line, One Handshake

MEF builds the horizontal cartoner, the pharmacode and vision checks and the case packer that follow the tray loader, so the whole line is engineered with one control handshake and commissioned by one team from Pune.

GMP Construction

SS304 frame and cladding, open design for line clearance, polycarbonate guarding with interlocked doors and no hidden ledges where glass fragments can collect. SS316 parts can be specified where your URS asks for them.

Validation-Ready Documentation

Recipes, user levels and alarm history are built in, with audit trail and electronic records available for Part 11-ready configurations. DQ, IQ and OQ protocols and FAT/SAT records are supplied with the machine.

Vial pick and place machineVial tray loading machineVial blister packing machineVial tray loaderAmpoule vial blister packingRobotic vial loadingInjection vial packagingBlister tray for vialsVial tray packing machinePharma tray loaderLyophilised vial handlingVial cartoning line

How a Vial Pick and Place Cell Works

From the labeller outfeed to a checked, full tray at the cartoner infeed.

1Vial InfeedLabelled vials arrive single file; a feed screw spaces them to the tray pocket pitch.
2Collate a RowA row of vials is held in a collating nest, ready for the pick head.
3Tray DenestAn empty blister tray drops from the magazine onto the indexing tray conveyor.
4Pick and PlaceThe robot lifts the row and places it into the tray pockets at controlled speed.
5Check and TransferThe camera checks every pocket; good trays go to the cartoner, others to the reject lane.

Technical Specifications

Indicative figures. The achievable rate depends on vial diameter, tray pattern and pick head - send your vial and tray samples and target output and we will confirm it before quoting.

Vial Range2 ml to 50 ml tubular and moulded glass vials (for example 2R to 50R formats); other sizes on request
Vial TypesLiquid and lyophilised (freeze-dried) vials with flip-off seals; plastic vials on request
Tray Patterns1, 2, 5 and 10 pockets, single or double row; custom patterns on request
Tray MaterialsThermoformed PVC, PET or PP blister trays; paperboard inserts on request
Indicative Output60 - 150 vials/min depending on vial size, pattern and pick head
RobotDelta or SCARA robot with multi-pick head, chosen for the pattern and output
Pick HeadVacuum cups on the seal or soft mechanical fingers; 1 to 10 vials per pick
Vial InfeedSingle-lane from labeller or inspection machine, feed screw and collating nest; accumulation table optional
Tray SupplyTray magazine with denester and servo-indexed tray conveyor
Pocket CheckVision check of every pocket for vial presence and upright position; seal colour check optional
RejectsAutomatic reject lane for incomplete or faulty trays; reject and good counts per batch
ControlsPLC with colour touchscreen HMI (Siemens, Mitsubishi or Delta to suit your plant standard), recipes, user levels
Data IntegrityAudit trail, electronic records and alarm history for Part 11-ready configurations
ConstructionSS304 frame and cladding; glass-contact parts in food-grade polymer; SS316 on request
DocumentationDQ, IQ and OQ protocols, FAT and SAT records, material certificates, manuals and spares list

Optional Features

  • Horizontal cartoner integration - full trays fed straight into the carton with the leaflet, see our horizontal cartoner
  • Seal colour and label presence check in the same vision station - see vision inspection systems
  • Pharmacode and 2D code reading on the vial label before placing - see pharmacode inspection
  • Infeed accumulation table to absorb short stops of the labeller or cartoner
  • Lidding station integration for trays sealed with a paper or foil lid
  • Ampoule and cartridge format parts for lines that pack more than vials
  • Part 11-ready HMI with audit trail and electronic records - see our 21 CFR Part 11 guide
  • Validation document pack with DQ, IQ and OQ protocols - see IQ, OQ and PQ explained

Key Features

  • Multi-pick head places a full row of vials per cycle
  • Feed screw and collating nest set the vial pitch to the tray pocket pitch
  • Tray magazine and denester with servo-indexed tray conveyor
  • Vision check of every pocket before the tray leaves the cell
  • Reject lane for incomplete trays, with batch counts on the HMI
  • Colour-coded format parts and stored recipes for each vial and tray
  • Glass-contact parts in food-grade polymer; open design for line clearance
  • Interlocked polycarbonate guarding; machine stops safely on a door opening or vial jam
Layout of a vial tray loading cell: vial infeed with feed screw, collating nest, robot, tray magazine and denester, indexing tray conveyor, vision check, reject lane and transfer to horizontal cartoner
Typical cell - vial infeed and collating, robot, tray magazine, pocket check, reject lane and cartoner hand-off.

Industries & Applications

  • Injectables: liquid and lyophilised vials - antibiotics, vaccines, biologics and hormones - into 5 and 10-pocket trays
  • Veterinary: single and multi-dose injectable vials into trays and cartons
  • Diagnostics: reagent and control vials into kit trays before cartoning
  • Cosmetics and nutraceuticals: serum vials and ampoule-style vials into display trays

FAQs: Vial Pick and Place into Blister Trays

What is a vial tray loading machine?
A vial tray loading machine takes vials from the filling or labelling line and places them into the pockets of a thermoformed blister tray, ready for cartoning. It replaces the manual tray table found after the labeller on many injectable lines. MEF uses a robot with a multi-pick head, a tray magazine and a vision check, so each tray reaches the cartoner full and correctly loaded.
How many vials per minute can a vial pick and place machine handle?
Indicative rates are 60 - 150 vials per minute for one robot. The real figure depends on the vial diameter, the tray pattern and how many vials the head picks per cycle - a 5-pocket head on 10 ml vials runs very differently from a single pick on 50 ml vials. We calculate the rate for your vial and tray before quoting and, if needed, add a second robot or a second tray lane.
Can the same machine handle different vial sizes and tray patterns?
Yes. Each vial size and tray pattern has its own recipe and a set of format parts - feed screw, collating nest, pick head and tray guides. The operator changes the parts and selects the recipe, and the robot positions and speeds for that format are loaded automatically. The size range to be covered should be listed in your URS so we design the pick head and nest for all of them.
How do you make sure no tray leaves with an empty pocket?
A camera above the tray conveyor inspects every tray after placing. It checks that each pocket holds one vial, upright, with its seal present. If any pocket fails, the tray goes to the reject lane and the count is logged. The reject function itself is challenged with test trays at start-up and during OQ, so you have documented evidence that it works.
Should I load vials into trays manually, with a mechanical loader or with a robot?
Manual loading suits low volumes and many short batches. A dedicated mechanical loader is compact and fast for one vial and one tray format. A robot costs more at the start but changes format in software and parts, which suits plants that pack several vial sizes and tray patterns on one line. Our vial blister tray packing guide compares the three in detail.
Will the robot damage the flip-off seal or break glass vials?
The pick head is chosen for your vial: vacuum cups on the flat top of the flip-off seal for most vials, or soft mechanical fingers around the body where the seal is domed or coloured caps must not be marked. Glass-contact parts are polymer and the placing move slows before the pocket. We run your vials and trays during FAT to prove it. Our vial handling problems guide covers the usual causes of breakage and jams.
Is the vial tray loader suitable for GMP and 21 CFR Part 11?
The machine is built for GMP areas - SS304 frame, open design for cleaning and line clearance, interlocked guarding. The HMI has user levels and recipe protection, and audit trail and electronic records are available for Part 11-ready configurations. Compliance itself depends on how you validate and use the system; we supply DQ, IQ and OQ protocols and support qualification on site. See our pharma validation support page.

Send Us Your Vial and Tray

Share vial samples or drawings, the blister tray (or the pattern you want), the line speed of your labeller and cartoner and your URS if you have one. We will design the pick head and cell, confirm the rate and send a quotation.