Symptom, cause, check, fix: the quick table
Start by finding the pattern. Does the fault happen at one position on the head, one lane, one tray lot, one vial size, or at random? Mark the pick-head cups, note the tray lot on every reject and log the time. The pattern usually points to the cause before any adjustment is made.
| Symptom | Likely causes | What to check | Fix |
|---|---|---|---|
| Broken or cracked vials | Back-pressure on accumulation; impact at a transfer; feed screw out of time; vial trapped under a guide | Where the fragments are found; conveyor speeds; screw timing; guide gaps | Reduce line pressure; smooth transfers; re-time screw; set guides to the vial drawing |
| Vials tipping over | Speed difference between conveyors; gap at a dead plate; sudden stops; light lyophilised vials | Speed ratio at each transfer; dead plate length and height; acceleration settings | Match speeds; shorten or level dead plates; soften starts and stops |
| Jams at the feed screw | Wrong screw for the vial; worn screw; vial diameter over tolerance; tipped vial entering | Screw marking vs recipe; wear on flights; vial lot dimensions | Fit correct screw; replace worn parts; reject tipped vials before the screw |
| Vial dropped by the pick head | Vacuum leak; worn cup; dirty or domed seal button; acceleration too high | Vacuum level per cup; cup lips; seal surface | Replace cups; clean or fit fingers instead; reduce acceleration |
| Vial left hanging or tilted in the pocket | Pocket too tight; tray position error; release too early or too high | Tray lot dimensions; tray registration on conveyor; release height in recipe | Correct tray or pocket spec; fix registration; lower release point |
| Empty pocket | Missing vial in the collating nest; pick failure on one cup; vial pulled back out on release | Nest presence sensor; vacuum per cup; blow-off timing | Fix nest detection; replace cup; adjust blow-off |
| Two trays denested, or none | Trays nesting too tightly; static; warped trays; stack too heavy | Tray stacking lugs; humidity; stack height in magazine | Change tray design or lot; ionise; limit stack height |
| Marked or scuffed seals | Cup pressure too high; hard cup material; fingers closing on the seal | Cup type; Z-height; finger position | Softer cups; correct Z-height; grip the body, not the seal |
| False rejects at the tray check | Reflections on clear trays; lighting changed; tray colour or lot changed | Reject images; lighting; tray lot | Adjust lighting and inspection zone; re-teach with new tray lot |
Glass breakage and cracks
Type I borosilicate vials are strong in compression but vulnerable to impact on the heel and shoulder and to glass-on-glass contact under load. On a packing line, the energy comes from three places.
1. Line pressure
When the tray loader or cartoner stops and the labeller keeps running, vials pile up on the accumulation conveyor. The conveyor chain keeps pushing, and the front vials carry the load of every vial behind them. Pressure builds where vials meet a guide rail at an angle. Fixes: accumulation tables or turntables designed for low back-pressure, zone control that stops upstream conveyors instead of letting them push, and a sensible stop signal from the downstream machine back to the labeller.
2. Impact at transfers
Every change of direction or speed - a dead plate, a star wheel, the entry to the feed screw - is a place where a vial can hit something. Look for bright scuff marks on guides and on the vials themselves; they show where contact happens. Guides set wider than the vial let it rattle; guides set too narrow trap it. Set them from the vial drawing and its tolerance, with the format part marked for that vial.
3. Timing
A feed screw or star wheel that is out of time with the machine meets the vial instead of guiding it. After any mechanical work or change part swap, check timing at slow speed with vials, not just by eye.
Hairline cracks, especially at the heel, can let air and microbes in while the vial appears intact. When a vial breaks in the machine, treat the neighbouring vials as suspect: stop, remove the vials in the affected zone according to your procedure, clean out all fragments, inspect and record. Your QA team should define the zone and the disposition, not the operator on the night shift.
Tipping and falling vials
Tipping is common with small and light vials - 2R and 4R formats - and with lyophilised vials whose cake weighs very little. The causes are almost always mechanical.
- Speed differences at transfers. When a vial moves from one conveyor to another running at a different speed, its base is pushed or held back while its top keeps moving. Keep speed ratios small and consistent, and set them in the recipe for each vial size.
- Dead plates and gaps. A dead plate that is too long, not level with the conveyors or worn at the edges will tip light vials. Keep dead plates as short as possible and check their height after conveyor maintenance.
- Hard starts and stops. A conveyor that starts at full speed jerks vials backwards. Use acceleration ramps on the drives.
- Guide rails. Rails too low support the vial below its centre of gravity; set them to support the body at a height suited to each vial.
Remove fallen vials automatically before they reach the feed screw. A tipped vial entering a screw is the most common cause of a screw jam and a broken vial.
Pick head problems: drops, empty pockets and marked seals
On a robotic tray loader, the pick head holds a row of vials during a fast move. Most faults at this stage come from the grip.
Vacuum cups
- Check vacuum level on each cup, not only the header. One leaking cup can pass a header check and still drop its vial.
- Replace cups on a schedule. Lips harden and crack with time and cleaning agents, well before they look worn.
- A flip-off button with a raised logo, a domed top or residue from crimping may not seal. Clean it, choose a softer or bellows cup, or change to fingers that grip the vial body.
Release
If vials are released too high they drop and can bounce or tilt; if the blow-off is too strong or too late they can be pulled back up or pushed sideways. Release height and blow-off timing should be stored in the recipe for each vial and tray, and checked at FAT with your vials and trays.
Acceleration
Heavier vials (20R and above) and multi-vial heads carry real mass. If drops happen at the corners of the move, reduce acceleration before reducing speed; the output loss is usually smaller.
Tray problems: denesting and pocket fit
Many problems blamed on the machine start with the tray. Pocket dimensions, stacking features and flatness all vary with tooling and material lot.
- Keep a tray drawing with tolerances and check incoming lots against it, at least pocket diameter, pocket depth and pitch.
- Trays that nest tightly or carry static cling together; stacking lugs and an ioniser at the magazine help. Dry, air-conditioned packing halls make static worse.
- Do not overfill the magazine. The weight of a tall stack can press trays together and cause double denesting.
- If a new tray lot causes hanging vials, measure it before adjusting the machine. Moving the machine to suit a bad lot moves it away from the good ones.
- Treat a new tray supplier or tool as a change control item with a machine trial.
Our vial blister tray packing guide covers tray design and the details that make trays machinable.
Vision checks and rejects you can trust
The tray check is the last control before the cartoner closes the product in. Two failure modes matter: false rejects, which waste product and time, and missed rejects, which put an incomplete pack on the market.
- False rejects on clear trays usually come from reflections. Lighting geometry and the inspection zone should be set up with real trays from each supplier, and re-checked when a tray lot or colour changes.
- Missed rejects are prevented by challenge tests. Keep a set of prepared test trays - one empty pocket, one tilted vial, one missing seal - and run them at every start-up and after changeovers. Record the result in the batch record.
- Confirm that rejected trays actually leave the line: a reject that is detected but not removed is the most dangerous fault of all. A sensor that confirms the tray reached the reject bin closes the loop.
For how vision systems are specified and tested, see our vision inspection systems page.
Preventive checklist
- Every start-up: challenge the tray check with test trays; confirm the reject bin is empty and the confirm sensor works; check format parts match the recipe.
- Every shift: look for glass fragments and scuff marks at transfers; check vacuum on each cup; clear the magazine of damaged trays.
- Weekly: inspect cups and replace any with hardened lips; check guide settings and dead plate heights; clean the camera window and lights.
- Monthly or per maintenance plan: check feed screw and star wheel timing; inspect screw flights for wear; review breakage and reject records for trends.
- At each tray or vial change: measure the first lot against the drawing and run a machine trial before release.
Keeping the right format parts and cups in stock is half of this list; our spare parts programme explains how we set up a recommended spares kit for each machine.