On this page
How the IP code works
The IP (Ingress Protection) code is defined in IEC 60529. It has two digits: the first for protection against solid objects and dust, the second for protection against water. An "X" means that property was not tested - IPX5 says nothing about dust.
| First digit | Protection against solids |
|---|---|
| 0 | Not protected |
| 1 | Objects of 50 mm and larger (back of a hand) |
| 2 | Objects of 12.5 mm and larger (a finger) |
| 3 | Objects of 2.5 mm and larger (tools, thick wires) |
| 4 | Objects of 1.0 mm and larger (thin wires) |
| 5 | Dust-protected: some dust may enter, but not enough to interfere with operation |
| 6 | Dust-tight: no dust ingress |
For packaging, 5 versus 6 matters more than it looks. Fine powders - milk powder, spices, pharmaceutical granules - migrate into anything dust-protected but not dust-tight, and conductive or abrasive dust inside a sensor or motor is a slow failure.
The second digit: protection against water
| Second digit | Protection against | Test in brief |
|---|---|---|
| 1-2 | Dripping water | Vertical drips; drips with the enclosure tilted up to 15° |
| 3 | Spraying water | Spray up to 60° from vertical |
| 4 | Splashing water | Splashing from any direction |
| 5 | Water jets | 6.3 mm nozzle, 12.5 l/min, from 2.5-3 m, at least 3 minutes |
| 6 | Powerful water jets | 12.5 mm nozzle, 100 l/min, from 2.5-3 m, at least 3 minutes |
| 7 | Temporary immersion | Immersion to 1 m for 30 minutes |
| 8 | Continuous immersion | Conditions agreed with the manufacturer, more severe than 7 |
| 9 | High-pressure, high-temperature jets | Added to IEC 60529 by its 2013 amendment |
Up to 6, each level includes the ones below it. Above 6 the tests change character: immersion (7 and 8) is a slow, low-pressure test, while jets (5 and 6) and high-pressure cleaning (9) hit seals hard for a short time. A seal that survives one can fail the other, which is why good washdown components carry dual ratings such as IP66/IP67 or IP67/IP69K.
IP69K: where it comes from and what it tests
IP69K originated in the German standard DIN 40050-9 for road vehicles - trucks and equipment cleaned with steam and pressure washers - and is now carried by ISO 20653. The food industry adopted it because it resembles intensive hot-water cleaning. The test:
- Water at 80 °C, pressure 80-100 bar (8-10 MPa), flow 14-16 l/min.
- Nozzle 10-15 cm from the specimen.
- 30 seconds at each of four angles - 0°, 30°, 60° and 90° - with the specimen on a turntable at 5 rpm.
IEC 60529's own IPX9, added in 2013, is similar in intent, but the test details are not identical to ISO 20653. When a data sheet says "IP69", check which standard it refers to; if your URS says IP69K, ask for ISO 20653.
The test lasts two minutes on a new, dry-tested part. Aiming a pressure washer at a shaft seal or cable gland for ten minutes every night is a different load. Even IP69K parts last longer when the jet is kept off seals and joints.
What to specify for your environment
The table shows common practice for packaging machines. Your own cleaning procedure - chemical, temperature, pressure, frequency - should decide the final specification.
| Environment | Typical cleaning | Enclosures and junction boxes | Motors, sensors, HMIs |
|---|---|---|---|
| Dry pharma secondary packing (cartoning, case packing, inspection) | Dry cleaning, wipe-down with alcohol or disinfectant | IP54 cabinets are common; IP65 for machine-mounted boxes | Standard IP54-IP65 motors; IP65/IP67 sensors; IP65 HMI front |
| Pharma primary and powder areas | Wet wipe, occasional low-pressure rinse, fine dust | IP65, stainless | Dust-tight (6) sensors and motors; IP65/IP66 HMI in stainless housing |
| Dry food (snacks, masala, sugar, flour) | Dry cleaning, vacuum, compressed air | IP65; dust-tight matters most | IP65 or higher, dust-tight load cells on weighers |
| Food washdown (dairy, meat, sauces, ready meals) | Daily hot water and foam, pressure rinse | IP66 or IP69K, hygienic stainless design | IP66/IP69K stainless motors; IP67/IP69K sensors; stainless HMIs |
| Outdoor or semi-open end-of-line (sheds, loading bays) | Rain, dust, sun, humidity swings | IP65-IP66, UV-resistant, with a canopy and anti-condensation heater | IP65-IP66; UV-resistant cables |
Over-specifying has costs: IP69K stainless motors and sensors can cost several times their standard equivalents, and a sealed stainless cabinet in a dry pharma hall only adds heat-management problems. Specify for how the machine will actually be cleaned.
Two examples. A multihead weigher packing masala or milk powder is rarely washed with a hose, but fine dust reaches everything, so dust-tight load cells, sealed hoppers and IP65 or better electrics matter more than jet resistance. A checkweigher and metal detector on a sauce or meat line is hosed every shift, so the detector head, belt drive and reject unit need washdown-rated components and a frame that drains.
Motors, sensors, enclosures and HMIs
Motors and servos
Standard fan-cooled motors are often IP55, and the fan throws contaminated spray around the machine. In washdown areas, smooth-bodied stainless motors without fans, rated IP66 or IP69K, are the usual choice. Servo motors are commonly IP65 at the body; the shaft exit depends on a shaft seal, which is a wear part - add it to the spares list. Servo drives themselves are IP20 and live inside the control cabinet.
Sensors and connectors
Photoelectric and proximity sensors are available up to IP67/IP69K in stainless housings. An M12 connector keeps its rating only when mated and tightened; an unplugged socket left open is effectively IP00.
Enclosures
For washdown, choose stainless enclosures with a sloped roof so water runs off, stand-off mounting so the wall behind can be cleaned, and hygienic hinges and gaskets. Cabinet coolers and fans need their own rating - an IP54 fan filter on an IP66 cabinet makes an IP54 cabinet.
HMIs
A panel-mounted HMI is usually rated IP65 or IP66 at the front only, and only when the gasket is correctly compressed in a flat cut-out. The rear is typically IP20. In washdown areas, use a stainless-housed HMI or mount the panel in a sealed enclosure.
IP rating is not hygienic design
An IP rating says water stays out. Hygienic design says dirt does not stay on. A dust-tight enclosure with a flat top, exposed threads and a crevice behind it is well sealed and hard to clean. The principles in EN 1672-2 and EHEDG guidance - sloped surfaces, no horizontal ledges, radiused corners, continuous welds, stand-offs and open frames - matter as much as the digits. The choice of steel matters too, as covered in SS304 vs SS316L. For machines sold into Europe, hygiene requirements for food and pharmaceutical machinery are part of the essential requirements under the EU Machinery Regulation.
Pitfalls we see on site
- Component rating mistaken for machine rating. "IP65 machine" means little unless the whole assembly was tested. The real rating is the weakest point: a gland, a door, a fan filter, an HMI rear.
- Cable glands. A gland is rated only with a cable of the right diameter and the correct sealing insert. Unused entries must be blanked with rated plugs, and entries should come from below.
- Condensation. A warm enclosure hosed with cold water cools quickly and pulls moist air in through the seals. Pressure-compensation vents and anti-condensation heaters prevent the "sealed box full of water" failure.
- Damaged gaskets. Door gaskets crushed by over-tightening or cut during maintenance lose the rating silently. Include them in the preventive maintenance checklist.
- Chemicals. IP tests use clean water. Caustic foams, acids and hypochlorite can harden or swell seals, so check gasket and cable-jacket materials against your cleaning chemicals.
- US equivalents. NEMA 4X enclosures are broadly comparable to IP66 for water, but the NEMA types also cover corrosion and other conditions, so they are not direct equivalents.
At MEF we ask about the cleaning method, chemicals and pressure at URS stage, because they decide the component list more than the product does.
Frequently asked questions
Is IP67 better than IP66?
What does IP69K mean?
What IP rating is needed for food washdown?
Is IP65 enough for a pharma packaging machine?
Does an IP rating cover cleaning chemicals?
References
- IEC: Ingress Protection (IP) ratings
- IEC 60529:1989+AMD1:1999+AMD2:2013 - Degrees of protection provided by enclosures (IP Code)
- ISO 20653:2023 - Road vehicles - Degrees of protection (IP code)
Regulatory text changes. Always check the current version of a regulation before relying on it; this article reflects our reading as of 29 Sep 2026 and is not legal advice.