On this page
What changed in revised Schedule M
Schedule M of the Drugs Rules, 1945 sets India's good manufacturing practice requirements. The Ministry of Health notified a revised version as G.S.R. 922(E) on 28 December 2023. The earlier text was largely about premises and basic practices; the revision moves Indian GMP towards a quality-system approach and spells out expectations that auditors previously applied informally.
| New or strengthened element | What it asks | What it means for packaging equipment |
|---|---|---|
| Pharmaceutical Quality System (PQS) | A documented quality system covering the product lifecycle, with management responsibility | Equipment, changes and deviations handled within the system, not informally by engineering |
| Quality Risk Management (QRM) | Decisions based on documented risk assessment | Qualification depth, upgrade priorities and change impact justified by risk |
| Product Quality Review (PQR) | Regular review of each product's quality data | Reject rates, deviations and complaints traced back to line performance |
| Qualification and validation | Explicitly covers premises, utilities and equipment, with DQ, IQ, OQ and PQ | Every packaging machine needs qualification records - including older machines |
| Computerised systems | Validation; IQ/OQ of hardware and software; secure backup; an extra check on manually entered critical data; controls against unauthorised changes, with audit trails | PLC, HMI and vision software must have access control, audit trails and backups |
If you already work to EU GMP or supply WHO-prequalified or US products, most of this will be familiar. For units that have worked only to the old Schedule M, the qualification and computerised-systems requirements are usually the largest change on the packaging floor.
Timelines, and where things stand
| Category | Deadline | Status |
|---|---|---|
| Turnover above ₹250 crore | 6 months from notification (around end of June 2024) | Passed |
| Turnover up to ₹250 crore (MSME) | 12 months from notification, then extended by a notification of 11 February 2025 to 31 December 2025 for units that applied in Form A within three months, with a gap analysis and upgrade plan | Passed |
In November 2025 the DCGI ordered inspections of units that had not applied for the extension; reports at the time said roughly 1,700 of about 8,500 MSMEs had applied. In late December 2025 reports indicated that no further extension was expected and that risk-based inspections would begin from January 2026.
We have not found any further extension. According to available reports, revised Schedule M has been binding on all units since 1 January 2026. Confirm your own unit's position with your licensing authority, and treat any open item in your upgrade plan as an inspection risk now, not later.
Gap assessment checklist for existing packaging lines
Walk each line with production, engineering and QA together. For every "no", record the gap, the risk and the proposed action.
Qualification records
- Does each machine have a URS or equivalent, and IQ/OQ/PQ records - or a documented retrospective qualification?
- Do drawings match the machine as it stands today, after years of modifications?
- Are machine-mounted instruments (load cells, temperature controllers, pressure gauges) in the calibration programme?
- Is there a list of change parts per format, and are they identified and controlled?
Computerised systems and data integrity
- Does every person log in individually, or is there a shared password on the HMI?
- Can recipe or reject parameters be changed without a record of who, when, old value and new value?
- Is there a backup of the PLC, HMI and vision programs, and has a restore ever been tested?
- Are manually entered critical data - batch number, manufacturing and expiry dates - checked by a second person or by the system?
- Are software versions recorded, and are changes under change control?
Mix-up prevention
- Is printed batch and expiry information verified by camera (OCR/OCV) or only by periodic manual check?
- Are leaflets, cartons and labels checked by Pharmacode or barcode reading to catch wrong components?
- Does every reject station confirm that the rejected pack actually left the line, and is the reject bin lockable?
- Can the machine be fully cleared at line clearance, with no hidden places where cartons or leaflets collect?
Product contact and hygiene
- Are product-contact parts of suitable material, intact and cleanable?
- Can lubricant or wear debris reach product or primary packaging?
Qualifying an older machine that has no records
A machine installed years ago without IQ/OQ records is not automatically unusable, but it needs a documented basis for continued use. A workable approach, often called retrospective qualification:
- Write a short URS describing what the machine does today and which of its functions are GMP-critical.
- Produce as-built drawings - at minimum the electrical schematic, I/O list and a GA with product-contact parts identified.
- Record the current state: PLC, HMI and vision program backups, software versions, instrument calibration status, and product-contact materials where they can be established.
- Review the history: deviations, complaints, reject trends and maintenance records as evidence of reliable operation.
- Execute IQ/OQ on the GMP-critical functions: reject challenges, interlocks, code verification, recipe protection.
- Close or justify each gap in the risk assessment and upgrade plan.
Historical production data supports the case but does not replace testing the critical functions now. A reject system that has "never failed" has often simply never been challenged.
Upgrade, retrofit or replace?
Most Schedule M gaps on packaging lines sit in the controls, inspection and documentation, not in the mechanics. That makes many of them retrofits.
| Gap | Retrofit option | When replacement makes more sense |
|---|---|---|
| Shared logins, no audit trail | HMI (and if needed PLC) upgrade with user management, audit trail and reports | PLC hardware obsolete and mechanics worn |
| No automated code verification | OCR/OCV camera with reject and reject confirmation | Transport cannot hold packs steady enough to read |
| No component verification | Pharmacode or barcode readers on leaflet and carton feeds | Rarely - usually retrofittable |
| Missing qualification records | Retrospective qualification: as-built drawings, risk assessment, IQ/OQ | Never on its own - this is documentation |
| Unsuitable contact materials or uncleanable design | Replace contact parts where the design allows | Frame and product zone are fundamentally unsuitable |
| Manual format settings with no reference | Digital position indicators or scales on adjustment points | Frequent changeovers justify a servo-format machine |
If the retrofit list approaches half the cost of a new machine, and the machine is also slow or unreliable, get a replacement quotation before committing. A new machine arrives with qualification documents and Part 11 functions built in; a heavily modified old one carries its history into every inspection.
We assess existing lines against this checklist and quote retrofits where they make sense, including carton inspection and code verification on existing cartoners.
Prioritising by risk
Revised Schedule M expects quality risk management, so use it to order the upgrade plan. A simple approach:
- List every gap from the checklist, per line.
- Score severity by the harm to the patient if the gap leads to a failure: a wrong leaflet or wrong expiry date is high; a missing drawing is low.
- Score likelihood and detectability: is there another control that would catch the failure before release?
- Rank and schedule: high-severity, poorly detected gaps first, with dates and owners.
- Close with evidence: each fix qualified (see IQ OQ PQ) and recorded in the upgrade plan.
In practice the order on most packaging lines comes out as: mix-up prevention (component and code verification, reject confirmation), then primary pack integrity, then data integrity of GMP records, then documentation. If your products are on India's QR-code list, add that to the plan too - see serialization and QR codes.
Frequently asked questions
Is revised Schedule M now mandatory for MSME pharma units?
Does revised Schedule M require IQ, OQ and PQ for packaging machines?
Do old packaging machines have to be replaced to comply with revised Schedule M?
What does revised Schedule M say about computerised systems?
How should we prioritise upgrades on an existing packaging line?
References
- Revised Schedule M, G.S.R. 922(E), 28 Dec 2023 (CDSCO)
- Business Standard: Health ministry revises pharma manufacturing rules under Schedule M (Jan 2024)
- Pharmabiz: Schedule M compliance extended to 31 December 2025 for MSMEs (Feb 2025)
- Pharmabiz: DCGI orders inspections of non-applicant units (Nov 2025)
- Business Standard: Schedule M extension for MSME pharma firms unlikely (Dec 2025)
Regulatory text changes. Always check the current version of a regulation before relying on it; this article reflects our reading as of 29 Sep 2026 and is not legal advice.